dmidecode - hk 11
# dmidecode 3.3
Getting SMBIOS data from sysfs.
SMBIOS 3.6.0 present.
# SMBIOS implementations newer than version 3.3.0 are not
# fully supported by this version of dmidecode.
Table at 0x000E7390.
Handle 0x0000, DMI type 0, 26 bytes
BIOS Information
Vendor: American Megatrends International, LLC.
Version: NSHH051052
Release Date: 04/25/2024
Address: 0xF0000
Runtime Size: 64 kB
ROM Size: 64 MB
Characteristics:
PCI is supported
BIOS is upgradeable
BIOS shadowing is allowed
Boot from CD is supported
Selectable boot is supported
BIOS ROM is socketed
EDD is supported
Japanese floppy for NEC 9800 1.2 MB is supported (int 13h)
Japanese floppy for Toshiba 1.2 MB is supported (int 13h)
5.25"/360 kB floppy services are supported (int 13h)
5.25"/1.2 MB floppy services are supported (int 13h)
3.5"/720 kB floppy services are supported (int 13h)
3.5"/2.88 MB floppy services are supported (int 13h)
Print screen service is supported (int 5h)
Serial services are supported (int 14h)
Printer services are supported (int 17h)
CGA/mono video services are supported (int 10h)
ACPI is supported
USB legacy is supported
BIOS boot specification is supported
Targeted content distribution is supported
UEFI is supported
BIOS Revision: 5.32
Handle 0x0001, DMI type 1, 27 bytes
System Information
Manufacturer: N/A
Product Name: X640 G50
Version: Eagle Stream
Wake-up Type: Power Switch
SKU Number: 98001940
Family: Rack
Handle 0x0002, DMI type 2, 15 bytes
Base Board Information
Manufacturer: N/A
Product Name: 60EA32X
Version: 24003523
Asset Tag: N/A
Features:
Board is a hosting board
Board is replaceable
Location In Chassis: To Be Filled By O.E.M.
Chassis Handle: 0x0003
Type: Motherboard
Contained Object Handles: 0
Handle 0x0003, DMI type 3, 22 bytes
Chassis Information
Manufacturer: N/A
Type: Rack Mount Chassis
Lock: Present
Version: To be filled by O.E.M.
Asset Tag: To be filled by O.E.M.
Boot-up State: Safe
Power Supply State: Safe
Thermal State: Safe
Security Status: None
OEM Information: 0x00000000
Height: 4 U
Number Of Power Cords: 1
Contained Elements: 0
SKU Number: To Be Filled By O.E.M.
Handle 0x0004, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J105_IO_BOARD
Internal Connector Type: Other
External Reference Designator: J2_USB0&1_J3_VGA_J4_Mgmt_J5_Type-C_J6_M.2_1_J7_M.2_2_J8_MIPI60
External Connector Type: None
Port Type: None
Handle 0x0005, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J156_MCIO_x4_1
Internal Connector Type: Other
External Reference Designator: SATA0~3
External Connector Type: None
Port Type: SATA
Handle 0x0006, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J157_MCIO_x4_2
Internal Connector Type: Other
External Reference Designator: SATA4~7
External Connector Type: None
Port Type: SATA
Handle 0x0007, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J158_MCIO_x4_3
Internal Connector Type: Other
External Reference Designator: SATA8~11
External Connector Type: None
Port Type: SATA
Handle 0x0008, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J34_MCIO_x8_4
Internal Connector Type: Other
External Reference Designator: MCIO_x8_C0P0_0
External Connector Type: None
Port Type: None
Handle 0x0009, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J53_MCIO_x8_5
Internal Connector Type: Other
External Reference Designator: MCIO_x8_C0P0_1
External Connector Type: None
Port Type: None
Handle 0x000A, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J33_MCIO_x8_6
Internal Connector Type: Other
External Reference Designator: MCIO_x8_C0P1_0
External Connector Type: None
Port Type: None
Handle 0x000B, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J36_MCIO_x8_7
Internal Connector Type: Other
External Reference Designator: MCIO_x8_C0P1_1
External Connector Type: None
Port Type: None
Handle 0x000C, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J39_MCIO_x8_8
Internal Connector Type: Other
External Reference Designator: MCIO_x8_C0P2_0
External Connector Type: None
Port Type: None
Handle 0x000D, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J48_MCIO_x8_9
Internal Connector Type: Other
External Reference Designator: MCIO_x8_C0P2_1
External Connector Type: None
Port Type: None
Handle 0x000E, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J40_MCIO_x8_10
Internal Connector Type: Other
External Reference Designator: MCIO_x8_C0P3_0
External Connector Type: None
Port Type: None
Handle 0x000F, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J41_MCIO_x8_11
Internal Connector Type: Other
External Reference Designator: MCIO_x8_C0P3_1
External Connector Type: None
Port Type: None
Handle 0x0010, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J42_MCIO_x8_12
Internal Connector Type: Other
External Reference Designator: MCIO_x8_C0P4_0
External Connector Type: None
Port Type: None
Handle 0x0011, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J43_MCIO_x8_13
Internal Connector Type: Other
External Reference Designator: MCIO_x8_C0P4_1
External Connector Type: None
Port Type: None
Handle 0x0012, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J35_MCIO_x8_14
Internal Connector Type: Other
External Reference Designator: MCIO_x8_C1P0_0
External Connector Type: None
Port Type: None
Handle 0x0013, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J54_MCIO_x8_15
Internal Connector Type: Other
External Reference Designator: MCIO_x8_C1P0_1
External Connector Type: None
Port Type: None
Handle 0x0014, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J55_MCIO_x8_16
Internal Connector Type: Other
External Reference Designator: MCIO_x8_C1P1_0
External Connector Type: None
Port Type: None
Handle 0x0015, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J56_MCIO_x8_17
Internal Connector Type: Other
External Reference Designator: MCIO_x8_C1P1_1
External Connector Type: None
Port Type: None
Handle 0x0016, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J50_MCIO_x8_18
Internal Connector Type: Other
External Reference Designator: MCIO_x8_C1P2_0
External Connector Type: None
Port Type: None
Handle 0x0017, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J51_MCIO_x8_19
Internal Connector Type: Other
External Reference Designator: MCIO_x8_C1P2_1
External Connector Type: None
Port Type: None
Handle 0x0018, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J45_MCIO_x8_20
Internal Connector Type: Other
External Reference Designator: MCIO_x8_C1P3_0
External Connector Type: None
Port Type: None
Handle 0x0019, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J46_MCIO_x8_21
Internal Connector Type: Other
External Reference Designator: MCIO_x8_C1P3_1
External Connector Type: None
Port Type: None
Handle 0x001A, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J44_MCIO_x8_22
Internal Connector Type: Other
External Reference Designator: MCIO_x8_C1P4_0
External Connector Type: None
Port Type: None
Handle 0x001B, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J47_MCIO_x8_23
Internal Connector Type: Other
External Reference Designator: MCIO_x8_C1P4_1
External Connector Type: None
Port Type: None
Handle 0x001C, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J112_MCIO_x8_24
Internal Connector Type: Other
External Reference Designator: DELTA
External Connector Type: None
Port Type: None
Handle 0x001D, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J100
Internal Connector Type: Access Bus (USB)
External Reference Designator: FP_USB0&1
External Connector Type: Access Bus (USB)
Port Type: USB
Handle 0x001E, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J85_SMART_NIC
Internal Connector Type: None
External Reference Designator: SMART_NIC
External Connector Type: None
Port Type: None
Handle 0x001F, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J58 - VROC_KEY
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0020, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J66 - Front_Panel
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0021, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J70 - BIOS_Advance
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0022, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J71 - BIOS_Recovery
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0023, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J79 - CMOS_CLR
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0024, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J92 - TPCM
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0025, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J187 - LKG_DET
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0026, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J80 - SMB_0_HDD
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0027, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J81 - SMB_1_HDD
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0028, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J192 - IPMB_RAID
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0029, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J67 - MFG
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x002A, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J68 - PWD_CLR
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x002B, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J69 - ME_RCVY
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x002C, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J78 - BAT
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x002D, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J87 - VGA_EN
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x002E, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J75 - BMC_UART
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x002F, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J190 - BMC_SOL
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0030, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J57 - BMC_EN
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0031, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J110 - CHSS_INT
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0032, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J49 - ASD_EN
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0033, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J89 - CPLD_JTAG
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0034, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J111 - OCP
Internal Connector Type: On Board IDE
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0035, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J128 - SYS_UART
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0036, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J116 - LQD_EN
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0037, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J61 - CPU0_FAN
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0038, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J64 - CPU1_FAN
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0039, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J73 - GPU_PWR1
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x003A, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J97 - GPU_PWR2
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x003B, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J77 - GPU_PWR3
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x003C, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J99 - GPU_PWR4
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x003D, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J76 - GPU_PWR5
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x003E, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J98 - GPU_PWR6
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x003F, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J72 - GPU_PWR7
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0040, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J96 - GPU_PWR8
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0041, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J88 - BOARD_PWR3
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0042, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J93 - BOARD_PWR2
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0043, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J86 - BOARD_PWR1
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0044, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J101 - BUSBAR_PWR1
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0045, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J119 - BUSBAR_PWR2
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0046, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J52 - HDD_BP_PWR1
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0047, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J60 - HDD_BP_PWR2
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0048, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J74 - HDD_BP_PWR3
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0049, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J162 - HDD_BP_PWR4
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x004A, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J107 - OCP_PWR
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x004B, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J95 - RISER_PWR1
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x004C, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J106 - RISER_PWR2
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x004D, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: PSU1
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x004E, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: PSU2
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x004F, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: PSU3
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0050, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: PSU4
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0051, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J59 - FAN1
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0052, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J62 - FAN2
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0053, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J63 - FAN3
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0054, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J65 - FAN4
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0055, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J90 - FAN5
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0056, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J102 - FAN6
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0057, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J103 - FAN7
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0058, DMI type 8, 9 bytes
Port Connector Information
Internal Reference Designator: J104 - FAN8
Internal Connector Type: Other
External Reference Designator: Not Specified
External Connector Type: None
Port Type: Other
Handle 0x0059, DMI type 10, 6 bytes
On Board Device Information
Type: Video
Status: Enabled
Description: To Be Filled By O.E.M.
Handle 0x005A, DMI type 11, 5 bytes
OEM Strings
String 1: 00
Handle 0x005B, DMI type 12, 5 bytes
System Configuration Options
Option 1: J71 BIOS Recovery Mode : 1-2 Normal(default), 2-3 BIOS Recovery
Option 2: J67 Manufacture Mode : 1-2 Normal(default), 2-3 Open Debug Message
Option 3: J70 BIOS ADVANCE FUNCTIONS : 1-2 Normal(default), 2-3 Open Debug Message
Option 4: J87 VGA_EN : 1-2 Normal operation(default), 2-3 Disable On Board VGA
Option 5: J69 Me Recovery Mode : 1-2 Normal(default), 2-3 Me force Update
Option 6: J68 Password Clear : 1-2 Normal(default), 2-3 Clear password
Option 7: J79 Clear CMOS : 1-2 Normal operation(default), 2-3 Clear CMOS
Handle 0x005C, DMI type 32, 20 bytes
System Boot Information
Status: No errors detected
Handle 0x005D, DMI type 39, 22 bytes
System Power Supply
Power Unit Group: 1
Location: PSU1
Name: CRPS2700D2
Manufacturer: Great Wall
Asset Tag: To Be Filled By O.E.M.
Model Part Number: To Be Filled By O.E.M.
Revision: 1.0.4
Max Power Capacity: 2700 W
Status: Present, OK
Type: Switching
Input Voltage Range Switching: Auto-switch
Plugged: Yes
Hot Replaceable: Yes
Handle 0x005E, DMI type 39, 22 bytes
System Power Supply
Power Unit Group: 2
Location: PSU2
Name: CRPS2700D2
Manufacturer: Great Wall
Asset Tag: To Be Filled By O.E.M.
Model Part Number: To Be Filled By O.E.M.
Revision: 1.0.4
Max Power Capacity: 2700 W
Status: Present, OK
Type: Switching
Input Voltage Range Switching: Auto-switch
Plugged: Yes
Hot Replaceable: Yes
Handle 0x005F, DMI type 39, 22 bytes
System Power Supply
Power Unit Group: 3
Location: PSU3
Name: CRPS2700D2
Manufacturer: Great Wall
Asset Tag: To Be Filled By O.E.M.
Model Part Number: To Be Filled By O.E.M.
Revision: 1.0.4
Max Power Capacity: 2700 W
Status: Present, OK
Type: Switching
Input Voltage Range Switching: Auto-switch
Plugged: Yes
Hot Replaceable: Yes
Handle 0x0060, DMI type 39, 22 bytes
System Power Supply
Power Unit Group: 4
Location: PSU4
Name: CRPS2700D2
Manufacturer: Great Wall
Asset Tag: To Be Filled By O.E.M.
Model Part Number: To Be Filled By O.E.M.
Revision: 1.0.4
Max Power Capacity: 2700 W
Status: Present, OK
Type: Switching
Input Voltage Range Switching: Auto-switch
Plugged: Yes
Hot Replaceable: Yes
Handle 0x0065, DMI type 44, 9 bytes
Unknown Type
Header and Data:
2C 09 65 00 FF FF 01 01 00
Handle 0x0066, DMI type 38, 18 bytes
IPMI Device Information
Interface Type: KCS (Keyboard Control Style)
Specification Version: 2.0
I2C Slave Address: 0x10
NV Storage Device: Not Present
Base Address: 0x0000000000000CA2 (I/O)
Register Spacing: Successive Byte Boundaries
Handle 0x0067, DMI type 45, 26 bytes
Unknown Type
Header and Data:
2D 1A 67 00 01 02 01 00 00 00 03 00 FF FF FF FF
FF FF FF FF 01 00 04 01 66 00
Strings:
BMC Firmware
51.68
D854
Handle 0x0068, DMI type 42, 17 bytes
Management Controller Host Interface
Host Interface Type: KCS: Keyboard Controller Style
Handle 0x0069, DMI type 133, 12 bytes
OEM-specific Type
Header and Data:
85 0C 69 00 00 B0 A5 70 00 40 00 00
Handle 0x006A, DMI type 16, 23 bytes
Physical Memory Array
Location: System Board Or Motherboard
Use: System Memory
Error Correction Type: Single-bit ECC
Maximum Capacity: 12 TB
Error Information Handle: Not Provided
Number Of Devices: 32
Handle 0x006B, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: 80 bits
Data Width: 64 bits
Size: 64 GB
Form Factor: DIMM
Set: None
Locator: CPU0_DIMMA0
Bank Locator: NODE 0
Type:
Type Detail: Synchronous Registered (Buffered)
Speed: 4800 MT/s
Manufacturer: Samsung
Asset Tag: CPU0_DIMMA0_AssetTag
Part Number: M321R8GA0BB0-CQKZJ
Rank: 2
Configured Memory Speed: 4400 MT/s
Minimum Voltage: 1.1 V
Maximum Voltage: 1.1 V
Configured Voltage: 1.1 V
Memory Technology: DRAM
Memory Operating Mode Capability: Volatile memory
Firmware Version: 0000
Module Manufacturer ID: Bank 1, Hex 0xCE
Module Product ID: 0xCE00
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: 64 GB
Cache Size: None
Logical Size: None
Handle 0x006C, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: Unknown
Data Width: Unknown
Size: No Module Installed
Form Factor: DIMM
Set: None
Locator: CPU0_DIMMA1
Bank Locator: NODE 0
Type: Unknown
Type Detail: Unknown
Speed: Unknown
Manufacturer: NO DIMM
Asset Tag: NO DIMM
Part Number: NO DIMM
Rank: Unknown
Configured Memory Speed: Unknown
Minimum Voltage: Unknown
Maximum Voltage: Unknown
Configured Voltage: Unknown
Memory Technology: Unknown
Memory Operating Mode Capability: None
Firmware Version: NO DIMM
Module Manufacturer ID: Unknown
Module Product ID: Unknown
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: None
Cache Size: None
Logical Size: None
Handle 0x006D, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: 80 bits
Data Width: 64 bits
Size: 64 GB
Form Factor: DIMM
Set: None
Locator: CPU0_DIMMB0
Bank Locator: NODE 0
Type:
Type Detail: Synchronous Registered (Buffered)
Speed: 4800 MT/s
Manufacturer: Samsung
Asset Tag: CPU0_DIMMB0_AssetTag
Part Number: M321R8GA0BB0-CQKZJ
Rank: 2
Configured Memory Speed: 4400 MT/s
Minimum Voltage: 1.1 V
Maximum Voltage: 1.1 V
Configured Voltage: 1.1 V
Memory Technology: DRAM
Memory Operating Mode Capability: Volatile memory
Firmware Version: 0000
Module Manufacturer ID: Bank 1, Hex 0xCE
Module Product ID: 0xCE00
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: 64 GB
Cache Size: None
Logical Size: None
Handle 0x006E, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: Unknown
Data Width: Unknown
Size: No Module Installed
Form Factor: DIMM
Set: None
Locator: CPU0_DIMMB1
Bank Locator: NODE 0
Type: Unknown
Type Detail: Unknown
Speed: Unknown
Manufacturer: NO DIMM
Asset Tag: NO DIMM
Part Number: NO DIMM
Rank: Unknown
Configured Memory Speed: Unknown
Minimum Voltage: Unknown
Maximum Voltage: Unknown
Configured Voltage: Unknown
Memory Technology: Unknown
Memory Operating Mode Capability: None
Firmware Version: NO DIMM
Module Manufacturer ID: Unknown
Module Product ID: Unknown
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: None
Cache Size: None
Logical Size: None
Handle 0x006F, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: 80 bits
Data Width: 64 bits
Size: 64 GB
Form Factor: DIMM
Set: None
Locator: CPU0_DIMMC0
Bank Locator: NODE 1
Type:
Type Detail: Synchronous Registered (Buffered)
Speed: 4800 MT/s
Manufacturer: Samsung
Asset Tag: CPU0_DIMMC0_AssetTag
Part Number: M321R8GA0BB0-CQKZJ
Rank: 2
Configured Memory Speed: 4400 MT/s
Minimum Voltage: 1.1 V
Maximum Voltage: 1.1 V
Configured Voltage: 1.1 V
Memory Technology: DRAM
Memory Operating Mode Capability: Volatile memory
Firmware Version: 0000
Module Manufacturer ID: Bank 1, Hex 0xCE
Module Product ID: 0xCE00
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: 64 GB
Cache Size: None
Logical Size: None
Handle 0x0070, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: Unknown
Data Width: Unknown
Size: No Module Installed
Form Factor: DIMM
Set: None
Locator: CPU0_DIMMC1
Bank Locator: NODE 1
Type: Unknown
Type Detail: Unknown
Speed: Unknown
Manufacturer: NO DIMM
Asset Tag: NO DIMM
Part Number: NO DIMM
Rank: Unknown
Configured Memory Speed: Unknown
Minimum Voltage: Unknown
Maximum Voltage: Unknown
Configured Voltage: Unknown
Memory Technology: Unknown
Memory Operating Mode Capability: None
Firmware Version: NO DIMM
Module Manufacturer ID: Unknown
Module Product ID: Unknown
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: None
Cache Size: None
Logical Size: None
Handle 0x0071, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: 80 bits
Data Width: 64 bits
Size: 64 GB
Form Factor: DIMM
Set: None
Locator: CPU0_DIMMD0
Bank Locator: NODE 1
Type:
Type Detail: Synchronous Registered (Buffered)
Speed: 4800 MT/s
Manufacturer: Samsung
Asset Tag: CPU0_DIMMD0_AssetTag
Part Number: M321R8GA0BB0-CQKZJ
Rank: 2
Configured Memory Speed: 4400 MT/s
Minimum Voltage: 1.1 V
Maximum Voltage: 1.1 V
Configured Voltage: 1.1 V
Memory Technology: DRAM
Memory Operating Mode Capability: Volatile memory
Firmware Version: 0000
Module Manufacturer ID: Bank 1, Hex 0xCE
Module Product ID: 0xCE00
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: 64 GB
Cache Size: None
Logical Size: None
Handle 0x0072, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: Unknown
Data Width: Unknown
Size: No Module Installed
Form Factor: DIMM
Set: None
Locator: CPU0_DIMMD1
Bank Locator: NODE 1
Type: Unknown
Type Detail: Unknown
Speed: Unknown
Manufacturer: NO DIMM
Asset Tag: NO DIMM
Part Number: NO DIMM
Rank: Unknown
Configured Memory Speed: Unknown
Minimum Voltage: Unknown
Maximum Voltage: Unknown
Configured Voltage: Unknown
Memory Technology: Unknown
Memory Operating Mode Capability: None
Firmware Version: NO DIMM
Module Manufacturer ID: Unknown
Module Product ID: Unknown
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: None
Cache Size: None
Logical Size: None
Handle 0x0073, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: 80 bits
Data Width: 64 bits
Size: 64 GB
Form Factor: DIMM
Set: None
Locator: CPU0_DIMME0
Bank Locator: NODE 2
Type:
Type Detail: Synchronous Registered (Buffered)
Speed: 4800 MT/s
Manufacturer: Samsung
Asset Tag: CPU0_DIMME0_AssetTag
Part Number: M321R8GA0BB0-CQKZJ
Rank: 2
Configured Memory Speed: 4400 MT/s
Minimum Voltage: 1.1 V
Maximum Voltage: 1.1 V
Configured Voltage: 1.1 V
Memory Technology: DRAM
Memory Operating Mode Capability: Volatile memory
Firmware Version: 0000
Module Manufacturer ID: Bank 1, Hex 0xCE
Module Product ID: 0xCE00
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: 64 GB
Cache Size: None
Logical Size: None
Handle 0x0074, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: Unknown
Data Width: Unknown
Size: No Module Installed
Form Factor: DIMM
Set: None
Locator: CPU0_DIMME1
Bank Locator: NODE 2
Type: Unknown
Type Detail: Unknown
Speed: Unknown
Manufacturer: NO DIMM
Asset Tag: NO DIMM
Part Number: NO DIMM
Rank: Unknown
Configured Memory Speed: Unknown
Minimum Voltage: Unknown
Maximum Voltage: Unknown
Configured Voltage: Unknown
Memory Technology: Unknown
Memory Operating Mode Capability: None
Firmware Version: NO DIMM
Module Manufacturer ID: Unknown
Module Product ID: Unknown
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: None
Cache Size: None
Logical Size: None
Handle 0x0075, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: 80 bits
Data Width: 64 bits
Size: 64 GB
Form Factor: DIMM
Set: None
Locator: CPU0_DIMMF0
Bank Locator: NODE 2
Type:
Type Detail: Synchronous Registered (Buffered)
Speed: 4800 MT/s
Manufacturer: Samsung
Asset Tag: CPU0_DIMMF0_AssetTag
Part Number: M321R8GA0BB0-CQKZJ
Rank: 2
Configured Memory Speed: 4400 MT/s
Minimum Voltage: 1.1 V
Maximum Voltage: 1.1 V
Configured Voltage: 1.1 V
Memory Technology: DRAM
Memory Operating Mode Capability: Volatile memory
Firmware Version: 0000
Module Manufacturer ID: Bank 1, Hex 0xCE
Module Product ID: 0xCE00
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: 64 GB
Cache Size: None
Logical Size: None
Handle 0x0076, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: Unknown
Data Width: Unknown
Size: No Module Installed
Form Factor: DIMM
Set: None
Locator: CPU0_DIMMF1
Bank Locator: NODE 2
Type: Unknown
Type Detail: Unknown
Speed: Unknown
Manufacturer: NO DIMM
Asset Tag: NO DIMM
Part Number: NO DIMM
Rank: Unknown
Configured Memory Speed: Unknown
Minimum Voltage: Unknown
Maximum Voltage: Unknown
Configured Voltage: Unknown
Memory Technology: Unknown
Memory Operating Mode Capability: None
Firmware Version: NO DIMM
Module Manufacturer ID: Unknown
Module Product ID: Unknown
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: None
Cache Size: None
Logical Size: None
Handle 0x0077, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: 80 bits
Data Width: 64 bits
Size: 64 GB
Form Factor: DIMM
Set: None
Locator: CPU0_DIMMG0
Bank Locator: NODE 3
Type:
Type Detail: Synchronous Registered (Buffered)
Speed: 4800 MT/s
Manufacturer: Samsung
Asset Tag: CPU0_DIMMG0_AssetTag
Part Number: M321R8GA0BB0-CQKZJ
Rank: 2
Configured Memory Speed: 4400 MT/s
Minimum Voltage: 1.1 V
Maximum Voltage: 1.1 V
Configured Voltage: 1.1 V
Memory Technology: DRAM
Memory Operating Mode Capability: Volatile memory
Firmware Version: 0000
Module Manufacturer ID: Bank 1, Hex 0xCE
Module Product ID: 0xCE00
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: 64 GB
Cache Size: None
Logical Size: None
Handle 0x0078, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: Unknown
Data Width: Unknown
Size: No Module Installed
Form Factor: DIMM
Set: None
Locator: CPU0_DIMMG1
Bank Locator: NODE 3
Type: Unknown
Type Detail: Unknown
Speed: Unknown
Manufacturer: NO DIMM
Asset Tag: NO DIMM
Part Number: NO DIMM
Rank: Unknown
Configured Memory Speed: Unknown
Minimum Voltage: Unknown
Maximum Voltage: Unknown
Configured Voltage: Unknown
Memory Technology: Unknown
Memory Operating Mode Capability: None
Firmware Version: NO DIMM
Module Manufacturer ID: Unknown
Module Product ID: Unknown
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: None
Cache Size: None
Logical Size: None
Handle 0x0079, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: 80 bits
Data Width: 64 bits
Size: 64 GB
Form Factor: DIMM
Set: None
Locator: CPU0_DIMMH0
Bank Locator: NODE 3
Type:
Type Detail: Synchronous Registered (Buffered)
Speed: 4800 MT/s
Manufacturer: Samsung
Asset Tag: CPU0_DIMMH0_AssetTag
Part Number: M321R8GA0BB0-CQKZJ
Rank: 2
Configured Memory Speed: 4400 MT/s
Minimum Voltage: 1.1 V
Maximum Voltage: 1.1 V
Configured Voltage: 1.1 V
Memory Technology: DRAM
Memory Operating Mode Capability: Volatile memory
Firmware Version: 0000
Module Manufacturer ID: Bank 1, Hex 0xCE
Module Product ID: 0xCE00
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: 64 GB
Cache Size: None
Logical Size: None
Handle 0x007A, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: Unknown
Data Width: Unknown
Size: No Module Installed
Form Factor: DIMM
Set: None
Locator: CPU0_DIMMH1
Bank Locator: NODE 3
Type: Unknown
Type Detail: Unknown
Speed: Unknown
Manufacturer: NO DIMM
Asset Tag: NO DIMM
Part Number: NO DIMM
Rank: Unknown
Configured Memory Speed: Unknown
Minimum Voltage: Unknown
Maximum Voltage: Unknown
Configured Voltage: Unknown
Memory Technology: Unknown
Memory Operating Mode Capability: None
Firmware Version: NO DIMM
Module Manufacturer ID: Unknown
Module Product ID: Unknown
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: None
Cache Size: None
Logical Size: None
Handle 0x007B, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: 80 bits
Data Width: 64 bits
Size: 64 GB
Form Factor: DIMM
Set: None
Locator: CPU1_DIMMA0
Bank Locator: NODE 4
Type:
Type Detail: Synchronous Registered (Buffered)
Speed: 4800 MT/s
Manufacturer: Samsung
Asset Tag: CPU1_DIMMA0_AssetTag
Part Number: M321R8GA0BB0-CQKZJ
Rank: 2
Configured Memory Speed: 4400 MT/s
Minimum Voltage: 1.1 V
Maximum Voltage: 1.1 V
Configured Voltage: 1.1 V
Memory Technology: DRAM
Memory Operating Mode Capability: Volatile memory
Firmware Version: 0000
Module Manufacturer ID: Bank 1, Hex 0xCE
Module Product ID: 0xCE00
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: 64 GB
Cache Size: None
Logical Size: None
Handle 0x007C, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: Unknown
Data Width: Unknown
Size: No Module Installed
Form Factor: DIMM
Set: None
Locator: CPU1_DIMMA1
Bank Locator: NODE 4
Type: Unknown
Type Detail: Unknown
Speed: Unknown
Manufacturer: NO DIMM
Asset Tag: NO DIMM
Part Number: NO DIMM
Rank: Unknown
Configured Memory Speed: Unknown
Minimum Voltage: Unknown
Maximum Voltage: Unknown
Configured Voltage: Unknown
Memory Technology: Unknown
Memory Operating Mode Capability: None
Firmware Version: NO DIMM
Module Manufacturer ID: Unknown
Module Product ID: Unknown
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: None
Cache Size: None
Logical Size: None
Handle 0x007D, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: 80 bits
Data Width: 64 bits
Size: 64 GB
Form Factor: DIMM
Set: None
Locator: CPU1_DIMMB0
Bank Locator: NODE 4
Type:
Type Detail: Synchronous Registered (Buffered)
Speed: 4800 MT/s
Manufacturer: Samsung
Asset Tag: CPU1_DIMMB0_AssetTag
Part Number: M321R8GA0BB0-CQKZJ
Rank: 2
Configured Memory Speed: 4400 MT/s
Minimum Voltage: 1.1 V
Maximum Voltage: 1.1 V
Configured Voltage: 1.1 V
Memory Technology: DRAM
Memory Operating Mode Capability: Volatile memory
Firmware Version: 0000
Module Manufacturer ID: Bank 1, Hex 0xCE
Module Product ID: 0xCE00
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: 64 GB
Cache Size: None
Logical Size: None
Handle 0x007E, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: Unknown
Data Width: Unknown
Size: No Module Installed
Form Factor: DIMM
Set: None
Locator: CPU1_DIMMB1
Bank Locator: NODE 4
Type: Unknown
Type Detail: Unknown
Speed: Unknown
Manufacturer: NO DIMM
Asset Tag: NO DIMM
Part Number: NO DIMM
Rank: Unknown
Configured Memory Speed: Unknown
Minimum Voltage: Unknown
Maximum Voltage: Unknown
Configured Voltage: Unknown
Memory Technology: Unknown
Memory Operating Mode Capability: None
Firmware Version: NO DIMM
Module Manufacturer ID: Unknown
Module Product ID: Unknown
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: None
Cache Size: None
Logical Size: None
Handle 0x007F, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: 80 bits
Data Width: 64 bits
Size: 64 GB
Form Factor: DIMM
Set: None
Locator: CPU1_DIMMC0
Bank Locator: NODE 5
Type:
Type Detail: Synchronous Registered (Buffered)
Speed: 4800 MT/s
Manufacturer: Samsung
Asset Tag: CPU1_DIMMC0_AssetTag
Part Number: M321R8GA0BB0-CQKZJ
Rank: 2
Configured Memory Speed: 4400 MT/s
Minimum Voltage: 1.1 V
Maximum Voltage: 1.1 V
Configured Voltage: 1.1 V
Memory Technology: DRAM
Memory Operating Mode Capability: Volatile memory
Firmware Version: 0000
Module Manufacturer ID: Bank 1, Hex 0xCE
Module Product ID: 0xCE00
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: 64 GB
Cache Size: None
Logical Size: None
Handle 0x0080, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: Unknown
Data Width: Unknown
Size: No Module Installed
Form Factor: DIMM
Set: None
Locator: CPU1_DIMMC1
Bank Locator: NODE 5
Type: Unknown
Type Detail: Unknown
Speed: Unknown
Manufacturer: NO DIMM
Asset Tag: NO DIMM
Part Number: NO DIMM
Rank: Unknown
Configured Memory Speed: Unknown
Minimum Voltage: Unknown
Maximum Voltage: Unknown
Configured Voltage: Unknown
Memory Technology: Unknown
Memory Operating Mode Capability: None
Firmware Version: NO DIMM
Module Manufacturer ID: Unknown
Module Product ID: Unknown
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: None
Cache Size: None
Logical Size: None
Handle 0x0081, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: 80 bits
Data Width: 64 bits
Size: 64 GB
Form Factor: DIMM
Set: None
Locator: CPU1_DIMMD0
Bank Locator: NODE 5
Type:
Type Detail: Synchronous Registered (Buffered)
Speed: 4800 MT/s
Manufacturer: Samsung
Asset Tag: CPU1_DIMMD0_AssetTag
Part Number: M321R8GA0BB0-CQKZJ
Rank: 2
Configured Memory Speed: 4400 MT/s
Minimum Voltage: 1.1 V
Maximum Voltage: 1.1 V
Configured Voltage: 1.1 V
Memory Technology: DRAM
Memory Operating Mode Capability: Volatile memory
Firmware Version: 0000
Module Manufacturer ID: Bank 1, Hex 0xCE
Module Product ID: 0xCE00
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: 64 GB
Cache Size: None
Logical Size: None
Handle 0x0082, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: Unknown
Data Width: Unknown
Size: No Module Installed
Form Factor: DIMM
Set: None
Locator: CPU1_DIMMD1
Bank Locator: NODE 5
Type: Unknown
Type Detail: Unknown
Speed: Unknown
Manufacturer: NO DIMM
Asset Tag: NO DIMM
Part Number: NO DIMM
Rank: Unknown
Configured Memory Speed: Unknown
Minimum Voltage: Unknown
Maximum Voltage: Unknown
Configured Voltage: Unknown
Memory Technology: Unknown
Memory Operating Mode Capability: None
Firmware Version: NO DIMM
Module Manufacturer ID: Unknown
Module Product ID: Unknown
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: None
Cache Size: None
Logical Size: None
Handle 0x0083, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: 80 bits
Data Width: 64 bits
Size: 64 GB
Form Factor: DIMM
Set: None
Locator: CPU1_DIMME0
Bank Locator: NODE 6
Type:
Type Detail: Synchronous Registered (Buffered)
Speed: 4800 MT/s
Manufacturer: Samsung
Asset Tag: CPU1_DIMME0_AssetTag
Part Number: M321R8GA0BB0-CQKZJ
Rank: 2
Configured Memory Speed: 4400 MT/s
Minimum Voltage: 1.1 V
Maximum Voltage: 1.1 V
Configured Voltage: 1.1 V
Memory Technology: DRAM
Memory Operating Mode Capability: Volatile memory
Firmware Version: 0000
Module Manufacturer ID: Bank 1, Hex 0xCE
Module Product ID: 0xCE00
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: 64 GB
Cache Size: None
Logical Size: None
Handle 0x0084, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: Unknown
Data Width: Unknown
Size: No Module Installed
Form Factor: DIMM
Set: None
Locator: CPU1_DIMME1
Bank Locator: NODE 6
Type: Unknown
Type Detail: Unknown
Speed: Unknown
Manufacturer: NO DIMM
Asset Tag: NO DIMM
Part Number: NO DIMM
Rank: Unknown
Configured Memory Speed: Unknown
Minimum Voltage: Unknown
Maximum Voltage: Unknown
Configured Voltage: Unknown
Memory Technology: Unknown
Memory Operating Mode Capability: None
Firmware Version: NO DIMM
Module Manufacturer ID: Unknown
Module Product ID: Unknown
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: None
Cache Size: None
Logical Size: None
Handle 0x0085, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: 80 bits
Data Width: 64 bits
Size: 64 GB
Form Factor: DIMM
Set: None
Locator: CPU1_DIMMF0
Bank Locator: NODE 6
Type:
Type Detail: Synchronous Registered (Buffered)
Speed: 4800 MT/s
Manufacturer: Samsung
Asset Tag: CPU1_DIMMF0_AssetTag
Part Number: M321R8GA0BB0-CQKZJ
Rank: 2
Configured Memory Speed: 4400 MT/s
Minimum Voltage: 1.1 V
Maximum Voltage: 1.1 V
Configured Voltage: 1.1 V
Memory Technology: DRAM
Memory Operating Mode Capability: Volatile memory
Firmware Version: 0000
Module Manufacturer ID: Bank 1, Hex 0xCE
Module Product ID: 0xCE00
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: 64 GB
Cache Size: None
Logical Size: None
Handle 0x0086, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: Unknown
Data Width: Unknown
Size: No Module Installed
Form Factor: DIMM
Set: None
Locator: CPU1_DIMMF1
Bank Locator: NODE 6
Type: Unknown
Type Detail: Unknown
Speed: Unknown
Manufacturer: NO DIMM
Asset Tag: NO DIMM
Part Number: NO DIMM
Rank: Unknown
Configured Memory Speed: Unknown
Minimum Voltage: Unknown
Maximum Voltage: Unknown
Configured Voltage: Unknown
Memory Technology: Unknown
Memory Operating Mode Capability: None
Firmware Version: NO DIMM
Module Manufacturer ID: Unknown
Module Product ID: Unknown
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: None
Cache Size: None
Logical Size: None
Handle 0x0087, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: 80 bits
Data Width: 64 bits
Size: 64 GB
Form Factor: DIMM
Set: None
Locator: CPU1_DIMMG0
Bank Locator: NODE 7
Type:
Type Detail: Synchronous Registered (Buffered)
Speed: 4800 MT/s
Manufacturer: Samsung
Asset Tag: CPU1_DIMMG0_AssetTag
Part Number: M321R8GA0BB0-CQKZJ
Rank: 2
Configured Memory Speed: 4400 MT/s
Minimum Voltage: 1.1 V
Maximum Voltage: 1.1 V
Configured Voltage: 1.1 V
Memory Technology: DRAM
Memory Operating Mode Capability: Volatile memory
Firmware Version: 0000
Module Manufacturer ID: Bank 1, Hex 0xCE
Module Product ID: 0xCE00
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: 64 GB
Cache Size: None
Logical Size: None
Handle 0x0088, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: Unknown
Data Width: Unknown
Size: No Module Installed
Form Factor: DIMM
Set: None
Locator: CPU1_DIMMG1
Bank Locator: NODE 7
Type: Unknown
Type Detail: Unknown
Speed: Unknown
Manufacturer: NO DIMM
Asset Tag: NO DIMM
Part Number: NO DIMM
Rank: Unknown
Configured Memory Speed: Unknown
Minimum Voltage: Unknown
Maximum Voltage: Unknown
Configured Voltage: Unknown
Memory Technology: Unknown
Memory Operating Mode Capability: None
Firmware Version: NO DIMM
Module Manufacturer ID: Unknown
Module Product ID: Unknown
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: None
Cache Size: None
Logical Size: None
Handle 0x0089, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: 80 bits
Data Width: 64 bits
Size: 64 GB
Form Factor: DIMM
Set: None
Locator: CPU1_DIMMH0
Bank Locator: NODE 7
Type:
Type Detail: Synchronous Registered (Buffered)
Speed: 4800 MT/s
Manufacturer: Samsung
Asset Tag: CPU1_DIMMH0_AssetTag
Part Number: M321R8GA0BB0-CQKZJ
Rank: 2
Configured Memory Speed: 4400 MT/s
Minimum Voltage: 1.1 V
Maximum Voltage: 1.1 V
Configured Voltage: 1.1 V
Memory Technology: DRAM
Memory Operating Mode Capability: Volatile memory
Firmware Version: 0000
Module Manufacturer ID: Bank 1, Hex 0xCE
Module Product ID: 0xCE00
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: 64 GB
Cache Size: None
Logical Size: None
Handle 0x008A, DMI type 17, 92 bytes
Memory Device
Array Handle: 0x006A
Error Information Handle: Not Provided
Total Width: Unknown
Data Width: Unknown
Size: No Module Installed
Form Factor: DIMM
Set: None
Locator: CPU1_DIMMH1
Bank Locator: NODE 7
Type: Unknown
Type Detail: Unknown
Speed: Unknown
Manufacturer: NO DIMM
Asset Tag: NO DIMM
Part Number: NO DIMM
Rank: Unknown
Configured Memory Speed: Unknown
Minimum Voltage: Unknown
Maximum Voltage: Unknown
Configured Voltage: Unknown
Memory Technology: Unknown
Memory Operating Mode Capability: None
Firmware Version: NO DIMM
Module Manufacturer ID: Unknown
Module Product ID: Unknown
Memory Subsystem Controller Manufacturer ID: Unknown
Memory Subsystem Controller Product ID: Unknown
Non-Volatile Size: None
Volatile Size: None
Cache Size: None
Logical Size: None
Handle 0x008B, DMI type 19, 31 bytes
Memory Array Mapped Address
Starting Address: 0x00000000000
Ending Address: 0x0007FFFFFFF
Range Size: 2 GB
Physical Array Handle: 0x006A
Partition Width: 8
Handle 0x008C, DMI type 19, 31 bytes
Memory Array Mapped Address
Starting Address: 0x00100000000
Ending Address: 0x0807FFFFFFF
Range Size: 510 GB
Physical Array Handle: 0x006A
Partition Width: 8
Handle 0x008D, DMI type 19, 31 bytes
Memory Array Mapped Address
Starting Address: 0x08080000000
Ending Address: 0x1007FFFFFFF
Range Size: 512 GB
Physical Array Handle: 0x006A
Partition Width: 8
Handle 0x00B0, DMI type 7, 27 bytes
Cache Information
Socket Designation: L1-Cache
Configuration: Enabled, Not Socketed, Level 1
Operational Mode: Write Back
Location: Internal
Installed Size: 2560 kB
Maximum Size: 2560 kB
Supported SRAM Types:
Synchronous
Installed SRAM Type: Synchronous
Speed: Unknown
Error Correction Type: Single-bit ECC
System Type: Unified
Associativity: 12-way Set-associative
Handle 0x00B1, DMI type 7, 27 bytes
Cache Information
Socket Designation: L2-Cache
Configuration: Enabled, Not Socketed, Level 2
Operational Mode: Varies With Memory Address
Location: Internal
Installed Size: 64 MB
Maximum Size: 64 MB
Supported SRAM Types:
Synchronous
Installed SRAM Type: Synchronous
Speed: Unknown
Error Correction Type: Single-bit ECC
System Type: Unified
Associativity: 16-way Set-associative
Handle 0x00B2, DMI type 7, 27 bytes
Cache Information
Socket Designation: L3-Cache
Configuration: Enabled, Not Socketed, Level 3
Operational Mode: Varies With Memory Address
Location: Internal
Installed Size: 60 MB
Maximum Size: 60 MB
Supported SRAM Types:
Synchronous
Installed SRAM Type: Synchronous
Speed: Unknown
Error Correction Type: Single-bit ECC
System Type: Unified
Associativity: Other
Handle 0x00B3, DMI type 4, 50 bytes
Processor Information
Socket Designation: CPU0
Type: Central Processor
Family: Xeon
Manufacturer: Intel(R) Corporation
ID: F8 06 08 00 FF FB EB BF
Signature: Type 0, Family 6, Model 143, Stepping 8
Flags:
FPU (Floating-point unit on-chip)
VME (Virtual mode extension)
DE (Debugging extension)
PSE (Page size extension)
TSC (Time stamp counter)
MSR (Model specific registers)
PAE (Physical address extension)
MCE (Machine check exception)
CX8 (CMPXCHG8 instruction supported)
APIC (On-chip APIC hardware supported)
SEP (Fast system call)
MTRR (Memory type range registers)
PGE (Page global enable)
MCA (Machine check architecture)
CMOV (Conditional move instruction supported)
PAT (Page attribute table)
PSE-36 (36-bit page size extension)
CLFSH (CLFLUSH instruction supported)
DS (Debug store)
ACPI (ACPI supported)
MMX (MMX technology supported)
FXSR (FXSAVE and FXSTOR instructions supported)
SSE (Streaming SIMD extensions)
SSE2 (Streaming SIMD extensions 2)
SS (Self-snoop)
HTT (Multi-threading)
TM (Thermal monitor supported)
PBE (Pending break enabled)
Version: Intel(R) Xeon(R) Gold 6430
Voltage: 1.6 V
External Clock: 100 MHz
Max Speed: 3400 MHz
Current Speed: 2100 MHz
Status: Populated, Enabled
Upgrade:
L1 Cache Handle: 0x00B0
L2 Cache Handle: 0x00B1
L3 Cache Handle: 0x00B2
Asset Tag: UNKNOWN
Part Number: Not Specified
Core Count: 32
Core Enabled: 32
Thread Count: 64
Characteristics:
64-bit capable
Multi-Core
Hardware Thread
Execute Protection
Enhanced Virtualization
Power/Performance Control
Handle 0x00B4, DMI type 7, 27 bytes
Cache Information
Socket Designation: L1-Cache
Configuration: Enabled, Not Socketed, Level 1
Operational Mode: Write Back
Location: Internal
Installed Size: 2560 kB
Maximum Size: 2560 kB
Supported SRAM Types:
Synchronous
Installed SRAM Type: Synchronous
Speed: Unknown
Error Correction Type: Single-bit ECC
System Type: Unified
Associativity: 12-way Set-associative
Handle 0x00B5, DMI type 7, 27 bytes
Cache Information
Socket Designation: L2-Cache
Configuration: Enabled, Not Socketed, Level 2
Operational Mode: Varies With Memory Address
Location: Internal
Installed Size: 64 MB
Maximum Size: 64 MB
Supported SRAM Types:
Synchronous
Installed SRAM Type: Synchronous
Speed: Unknown
Error Correction Type: Single-bit ECC
System Type: Unified
Associativity: 16-way Set-associative
Handle 0x00B6, DMI type 7, 27 bytes
Cache Information
Socket Designation: L3-Cache
Configuration: Enabled, Not Socketed, Level 3
Operational Mode: Varies With Memory Address
Location: Internal
Installed Size: 60 MB
Maximum Size: 60 MB
Supported SRAM Types:
Synchronous
Installed SRAM Type: Synchronous
Speed: Unknown
Error Correction Type: Single-bit ECC
System Type: Unified
Associativity: Other
Handle 0x00B7, DMI type 4, 50 bytes
Processor Information
Socket Designation: CPU1
Type: Central Processor
Family: Xeon
Manufacturer: Intel(R) Corporation
ID: F8 06 08 00 FF FB EB BF
Signature: Type 0, Family 6, Model 143, Stepping 8
Flags:
FPU (Floating-point unit on-chip)
VME (Virtual mode extension)
DE (Debugging extension)
PSE (Page size extension)
TSC (Time stamp counter)
MSR (Model specific registers)
PAE (Physical address extension)
MCE (Machine check exception)
CX8 (CMPXCHG8 instruction supported)
APIC (On-chip APIC hardware supported)
SEP (Fast system call)
MTRR (Memory type range registers)
PGE (Page global enable)
MCA (Machine check architecture)
CMOV (Conditional move instruction supported)
PAT (Page attribute table)
PSE-36 (36-bit page size extension)
CLFSH (CLFLUSH instruction supported)
DS (Debug store)
ACPI (ACPI supported)
MMX (MMX technology supported)
FXSR (FXSAVE and FXSTOR instructions supported)
SSE (Streaming SIMD extensions)
SSE2 (Streaming SIMD extensions 2)
SS (Self-snoop)
HTT (Multi-threading)
TM (Thermal monitor supported)
PBE (Pending break enabled)
Version: Intel(R) Xeon(R) Gold 6430
Voltage: 1.6 V
External Clock: 100 MHz
Max Speed: 3400 MHz
Current Speed: 2100 MHz
Status: Populated, Enabled
Upgrade:
L1 Cache Handle: 0x00B4
L2 Cache Handle: 0x00B5
L3 Cache Handle: 0x00B6
Asset Tag: UNKNOWN
Part Number: Not Specified
Core Count: 32
Core Enabled: 32
Thread Count: 64
Characteristics:
64-bit capable
Multi-Core
Hardware Thread
Execute Protection
Enhanced Virtualization
Power/Performance Control
Handle 0x00BC, DMI type 168, 47 bytes
OEM-specific Type
Header and Data:
A8 2F BC 00 01 00 01 02 05 00 01 D0 00 00 00 00
7E F8 83 06 00 00 00 00 00 00 00 00 00 00 00 00
7F 00 07 00 00 00 00 00 00 00 00 00 00 00 00
Strings:
Member: OTA General Information
Handle 0x00BD, DMI type 14, 8 bytes
Group Associations
Name: Group: One Touch Activation (OTA)
Items: 1
0x00BC (OEM-specific)
Handle 0x00BE, DMI type 42, 131 bytes
Management Controller Host Interface
Host Interface Type: Network
Device Type: USB
idVendor: 0x046b
idProduct: 0xffb0
Protocol ID: 04 (Redfish over IP)
Host IP Assignment Type: Static
Host IP Address Format: IPv4
IPv4 Address: 169.254.0.18
IPv4 Mask: 255.255.0.0
Redfish Service IP Discovery Type: Static
Redfish Service IP Address Format: IPv4
IPv4 Redfish Service Address: 169.254.0.17
IPv4 Redfish Service Mask: 255.255.0.0
Redfish Service Port: 443
Redfish Service Vlan: 0
Redfish Service Hostname:
Handle 0x00BF, DMI type 9, 24 bytes
System Slot Information
Designation: OCP_C0P0
Type: x16 PCI Express 4
Current Usage: In Use
Length: Long
ID: 1
Characteristics:
3.3 V is provided
PME signal is supported
Bus Address: 0000:16:00.0
Data Bus Width: 0
Peer Devices: 0
Handle 0x00C0, DMI type 9, 24 bytes
System Slot Information
Designation: Slot2_CPU0
Type: x4 PCI Express 2
Current Usage: In Use
Length: Long
ID: 8
Characteristics:
3.3 V is provided
PME signal is supported
Bus Address: 0000:27:00.0
Data Bus Width: 0
Peer Devices: 0
Handle 0x00C1, DMI type 9, 24 bytes
System Slot Information
Designation: Slot3_CPU0
Type: x16
Current Usage: Available
Length: Long
Characteristics:
3.3 V is provided
PME signal is supported
Bus Address: 0000:37:01.0
Data Bus Width: 0
Peer Devices: 0
Handle 0x00C2, DMI type 9, 24 bytes
System Slot Information
Designation: Slot4_CPU0
Type: x16
Current Usage: Available
Length: Long
Characteristics:
3.3 V is provided
PME signal is supported
Bus Address: 0000:48:01.0
Data Bus Width: 0
Peer Devices: 0
Handle 0x00C3, DMI type 9, 24 bytes
System Slot Information
Designation: Slot5_CPU0
Type: x16
Current Usage: Available
Length: Long
Characteristics:
3.3 V is provided
PME signal is supported
Bus Address: 0000:59:01.0
Data Bus Width: 0
Peer Devices: 0
Handle 0x00C4, DMI type 9, 24 bytes
System Slot Information
Designation: Slot6_CPU1
Type: x16
Current Usage: Available
Length: Long
Characteristics:
3.3 V is provided
PME signal is supported
Bus Address: 0000:97:01.0
Data Bus Width: 0
Peer Devices: 0
Handle 0x00C5, DMI type 9, 24 bytes
System Slot Information
Designation: Slot7_CPU1
Type: x16
Current Usage: Available
Length: Long
Characteristics:
3.3 V is provided
PME signal is supported
Bus Address: 0000:a7:01.0
Data Bus Width: 0
Peer Devices: 0
Handle 0x00C6, DMI type 9, 24 bytes
System Slot Information
Designation: Slot8_CPU1
Type: x16
Current Usage: Available
Length: Long
Characteristics:
3.3 V is provided
PME signal is supported
Bus Address: 0000:b7:01.0
Data Bus Width: 0
Peer Devices: 0
Handle 0x00C7, DMI type 9, 24 bytes
System Slot Information
Designation: Slot9_CPU1
Type: x16
Current Usage: Available
Length: Long
Characteristics:
3.3 V is provided
PME signal is supported
Bus Address: 0000:c7:01.0
Data Bus Width: 0
Peer Devices: 0
Handle 0x00C8, DMI type 9, 24 bytes
System Slot Information
Designation: Slot10_CPU1
Type: x8 PCI Express 4
Current Usage: In Use
Length: Long
ID: 65
Characteristics:
3.3 V is provided
PME signal is supported
Bus Address: 0000:d8:00.0
Data Bus Width: 0
Peer Devices: 0
Handle 0x00C9, DMI type 9, 24 bytes
System Slot Information
Designation: CPU1_PE4_NVMe2
Type: x4
Current Usage: Available
Length: Long
Characteristics:
3.3 V is provided
PME signal is supported
Hot-plug devices are supported
Bus Address: 0000:d7:05.0
Data Bus Width: 0
Peer Devices: 0
Handle 0x00CA, DMI type 9, 24 bytes
System Slot Information
Designation: CPU1_PE4_NVMe3
Type: x4
Current Usage: Available
Length: Long
Characteristics:
3.3 V is provided
PME signal is supported
Hot-plug devices are supported
Bus Address: 0000:d7:07.0
Data Bus Width: 0
Peer Devices: 0
Handle 0x00CC, DMI type 221, 159 bytes
OEM-specific Type
Header and Data:
DD 9F CC 00 16 01 02 FF FF FF FF FF 03 04 FF FF
FF FF FF 05 06 FF FF FF FF FF 07 08 FF FF FF FF
FF 09 0A FF FF FF FF FF 0B 0C FF FF FF FF FF 0D
0E FF FF FF FF FF 0F 10 FF FF FF FF FF 11 12 FF
FF FF FF FF 13 14 FF FF FF FF FF 15 16 FF FF FF
FF FF 17 18 FF FF FF FF FF 19 1A FF FF FF FF FF
1B 1C FF FF FF FF FF 1D 1E FF FF FF FF FF 1F 20
FF FF FF FF FF 21 22 FF FF FF FF FF 23 24 FF FF
FF FF FF 25 26 FF FF FF FF FF 27 28 FF FF FF FF
FF 29 2A FF FF FF FF FF 2B 2C FF FF FF FF FF
Strings:
IFWI Version
N/A
ME FW Version
18:6.1.4.5
BIOS ACM Version
1.1.9
BMC FW Version
33.68.0000
FRU SDR Version
N/A
FRU Version
N/A
SDR Version
1
CPU uCODE1 Version
M10806F8_2C000351
CPU uCODE2 Version
M87806F8_2B000571
CPU uCODE3 Version
M87C06F2_21000200
CPU uCODE4 Version
M5D7BDC6E9D_EE4E5898
SINIT ACM Version
4A30E478
MRC Version
1.1.1.0372
QPIRC Version
1.1.1.0372
PSU FW Version
1.0.4
RSTeSataEFI Version
N/A
RSTesSataEFI Version
N/A
1GEFI Version
N/A
iBMCGOP Version
N/A
VMDDxeEfi Version
0DAD5A7A
RSTeSataRaidEfi Version
6F9F55A3
NvmDimmDriver Version
6AC86DA1
Handle 0x00CD, DMI type 13, 22 bytes
BIOS Language Information
Language Description Format: Long
Installable Languages: 2
en|US|iso8859-1
zh|CN|unicode
Currently Installed Language: en|US|iso8859-1
Handle 0x00CE, DMI type 41, 11 bytes
Onboard Device
Reference Designation: AST2600 VGA
Type: Video
Status: Enabled
Type Instance: 1
Bus Address: 0000:02:00.0
Handle 0x00CF, DMI type 41, 11 bytes
Onboard Device
Reference Designation: PCH SATA Controller
Type: SATA Controller
Status: Enabled
Type Instance: 1
Bus Address: 0000:00:17.0
Handle 0x00D0, DMI type 41, 11 bytes
Onboard Device
Reference Designation: PCH SATA Controller
Type: SATA Controller
Status: Enabled
Type Instance: 2
Bus Address: 0000:00:18.0
Handle 0x00D1, DMI type 41, 11 bytes
Onboard Device
Reference Designation: PCH SATA Controller
Type: SATA Controller
Status: Enabled
Type Instance: 3
Bus Address: 0000:00:19.0
Handle 0x00D2, DMI type 127, 4 bytes
End Of Table